Linear Actuator Duty Cycle and Thermal Derating: An OEM Engineering Guide to ED% Calculation, Motor Thermal Equilibrium, and Continuous-Duty BLDC Sourcing
Calculate linear actuator duty cycle, assess thermal derating, and compare continuous-duty options. Use the OEM checklist to prepare a supplier engineering RFQ.
Published and technically reviewed: November 4, 2026. Scope: global OEM selection of screw-driven electric linear actuators.
Executive conclusion: Linear actuator duty cycle is powered running time divided by total cycle time. A 20% ED rating is useful only alongside its stated load, speed, ambient temperature, cycle period, and maximum uninterrupted run time. It does not establish continuous service capability or a service-life guarantee. Higher ambient temperature, repeated starts, holding current, and screw friction can consume thermal margin. Compare the supplier's tested operating envelope with the complete machine profile before selecting a brushed DC, BLDC, or servo architecture. A 50% rating is intermittent; S1 continuous duty requires operation to thermal equilibrium at the declared load.
Evidence boundary: This guide provides engineering screening methods and explicitly hypothetical calculations, not measured product qualification results. Motor duty terminology does not certify the complete actuator, brake, controller, or machine. Supplier limits and application testing take precedence over the examples below.
Have cycle timing available? Use the continuous-duty guide and powered-time calculator to organize it before preparing your RFQ. The calculator does not approve thermal fit.

Product illustration: a finned actuator housing. Appearance alone does not establish a tested 100% duty rating.
1. The Root Cause of Linear Actuator Field Burnouts
Overheating can be confused with mechanical problems such as side loading, seal damage, or excessive screw friction. A useful failure review compares measured current and temperature against the supplier's rating conditions rather than relying on the duty percentage alone.
Hypothetical timing example: A conveyor diverter uses an actuator catalogued at 6,000 N and 20% ED. It pushes a 4,500 N load for 12 seconds, rests for 48 seconds, and repeats through an eight-hour shift. Its arithmetic duty is 12 / (12 + 48) × 100 = 20%. If extension takes eight seconds and retraction takes four, both belong in the powered-time total. Any energized holding period must also be declared because it can generate heat without visible motion. This calculation establishes timing only; it does not predict failure, warranty coverage, or approval at the installation temperature.
The selection problem is treating duty cycle as a complete thermal assessment. Electrical input becomes mechanical work and losses. Repeated cycles approach a repeating temperature profile; they need not cool to ambient after each stroke. The winding peak, controller temperature, and gearbox temperature must all remain within their own limits throughout that profile.
2. Key Takeaways for Sourcing and Design Teams
Before specifying or negotiating terms for custom linear actuators, OEM design teams and procurement leads should establish the following engineering baselines:
- Request both timing limits: A 20% rating does not automatically permit 20 minutes on followed by 80 minutes off. Confirm the manufacturer's cycle period and maximum uninterrupted run time; a ten-minute window is not universal.
- Specify installation temperature: Measure the air around the installed actuator, including enclosure heating and solar exposure. There is no universal percentage reduction for operation at 40°C or 60°C.
- Separate insulation class from assembly limits: Thermal class describes an insulation system. Magnets, brushes, seals, lubricant, electronics, and accessible surfaces may impose lower operating temperatures.
- Compare drivetrain losses: Sliding screws can dissipate more heat than ball screws at the same output point. Actual efficiency depends on lead, lubrication, preload, speed, and load; request data for the proposed configuration.
- Buy a rated envelope, not a motor label: BLDC can improve winding heat conduction and remove brush wear. It does not inherently establish S1 capability, and an appropriately rated brushed motor can also operate continuously.
3. First Principles: Thermal Rise and Newton's Law of Cooling
For preliminary screening, a lumped thermal model helps engineers identify missing supplier data. Real actuators contain several thermal masses and heat paths, so a one-node model cannot determine every internal hot spot.
3.1 Sources of Internal Heat Generation
An operating linear actuator generates heat through three distinct mechanisms:
P_loss = P_copper + P_iron + P_friction
- Copper losses:
P_copper = I_RMS² × R_winding. Doubling winding current quadruples copper loss if resistance is unchanged. Doubling thrust does not necessarily double total current because no-load losses and drivetrain efficiency also contribute. Use phase-winding current for a controlled three-phase motor, not DC supply current as a substitute. - Iron losses: Eddy-current and hysteresis losses occur in magnetic laminations. They vary with speed and excitation.
- Mechanical losses: Bearings, gears, bushings, screw interfaces, and seals dissipate power. Brake coils and controller electronics add separate heat sources when present.
3.2 Transient Heating and the Thermal Time Constant
For a constant loss input, fixed ambient, and a motor initially at ambient, a first-order approximation is:
temperature_rise(t) = P_loss × R_th × (1 - exp(-t / tau))
tau = R_th × C_thHere P_loss is watts, R_th is °C/W, and C_th is J/°C. Their product gives tau in seconds; use seconds for t as well, or convert both to minutes. At one time constant the rise is approximately 63.2% of its final value. Obtain the relevant winding-to-housing and housing-to-ambient parameters from the manufacturer or a documented heat-run test. Size alone cannot establish a reliable time constant.
3.3 The Cooling Phase
With power losses removed, a corresponding approximation is rise(t) = peak_rise × exp(-t / tau_cool). A stopped shaft-driven fan can alter the cooling path, while a sealed housing still transfers heat through conduction, internal convection, and its exterior surface. IP rating alone does not establish a cooling time constant or a fixed thermal penalty. For a passive linear model with unchanged boundary conditions, heating and cooling use the same time constant. Brief pauses may leave substantial residual heat for the next cycle.
4. International Standards: IEC 60034-1 Duty Classifications
Use the motor duty vocabulary in IEC 60034-1:2026 to make an RFQ precise. The current catalogue record identifies this edition as replacing the 2022 edition. Its scope concerns rotating machines; an actuator supplier must separately rate the complete screw, gearbox, brake, and controller assembly. Agree the applicable edition and declared duty with the supplier.
Duty Type S1: Continuous Running Duty
Operation at a constant load long enough to reach thermal equilibrium. Continuous capability applies at the declared load and cooling conditions. It does not mean the maximum peak thrust can be sustained indefinitely or that maintenance is unnecessary.
Duty Type S2: Short-Time Duty
Operation at constant load for a stated time, followed by enough de-energized rest to return close to ambient. A hatch that moves only occasionally may fit this type, subject to its actual operating sequence.
Duty Type S3: Intermittent Periodic Duty
Repeated loaded running and de-energized rest periods, with starting losses having no significant thermal effect. The cyclic duration factor is:
ED% = t_on / (t_on + t_off) × 100
The temperature can settle into a repeating cycle above ambient. Full cooling between every cycle is not an S3 requirement. State the cycle length as well as ED%, because equal percentages with different on-times can produce different peak temperatures.
Duty Type S4: Intermittent Periodic Duty with Starting
Repeated starting, loaded running, and rest periods where starting losses matter. Short jogging strokes deserve explicit current and starts-per-hour assessment. A current-limited drive or soft start changes the waveform, so do not assign a universal starting-current multiplier. Include electric braking and irregular loads when discussing whether another duty type better describes the machine.
5. Motor Insulation Classes and Thermal Aging
IEC 60085:2007 distinguishes insulating materials from complete insulation systems and provides a framework for thermal evaluation and class designation. Thermal class is not a universal permitted housing temperature or an approval to run every motor component at that temperature.
| Insulation class | Thermal class designation | What the OEM must confirm |
|---|---|---|
| A | 105°C | Complete insulation-system rating and permitted winding rise |
| E | 120°C | Same, including the measurement method |
| B | 130°C | Hot-spot allowance and installation ambient |
| F | 155°C | Whether magnets, electronics, or seals impose a lower limit |
| H | 180°C | Assembly qualification rather than wire enamel alone |
The familiar “life halves for each extra 10°C” statement is an approximate thermal-aging heuristic, not a universal actuator lifetime equation. Actual insulation endurance requires material/system-specific evaluation. It cannot predict brush wear, bearing fatigue, or grease life, and operation below a class designation does not automatically double the life of the complete actuator.
Overheating may damage winding insulation, weaken permanent magnets, accelerate brush wear, or degrade lubricant and seals. Each mechanism has different limits. Request the proposed magnet grade, lubricant operating range, controller temperature limit, and protection thresholds rather than applying one temperature to the entire assembly. A cool outer housing also does not prove that internal windings remain cool during a short overload.
6. Ambient Temperature Derating: Formulas and Calculations
Use the supplier's specified reference ambient, not an assumed universal 25°C. Measure local air temperature inside the machine, including nearby heat sources, solar radiation, orientation, and airflow restrictions. An actuator rated at one ambient may be unusable at another even if its calculated ED% is unchanged.
A Screening Model with Explicit Assumptions
For short repetitive cycles compared with the thermal time constant, negligible off-state heat, unchanged on-state losses, and unchanged thermal resistance, average temperature rise is approximately proportional to duty fraction. Under those assumptions:
headroom = T_cap - T_ambient
ED_est = ED_ref × (T_cap - T_ambient) / (T_cap - T_ref)T_cap is an agreed winding operating ceiling after the design margin, not automatically the insulation class number. There is no squared headroom factor here: at constant running current, average copper loss is proportional to duty fraction. If instead the question is allowable current at fixed duty, current can scale with the square root of available heat budget in a copper-loss-dominated model.
This estimate does not resolve individual winding peaks, temperature-dependent resistance, controller limits, starting losses, or heat from an energized holding brake. Where those effects matter, obtain a multi-node model or measured profile. Never use the calculation to raise the supplier's published rating.
Worked Ambient-Derating Example: Not a Product Rating
Assume a hypothetical 20% reference duty at 25°C, a 155°C insulation system, and a 10°C margin giving a winding ceiling of 145°C. Reference headroom is 145 - 25 = 120°C. At 40°C, the estimate is 20% × 105 / 120 = 17.5%. The table is reproducible arithmetic under the assumptions above, not empirical test data or a safe continuous-run schedule.
| Ambient temperature | Headroom to assumed 145°C ceiling | Headroom ratio | Estimated ED%, capped at reference rating | Procurement interpretation |
|---|---|---|---|---|
| 20°C | 125°C | 1.042 | 20.0% | Do not uprate above the supplier limit |
| 25°C | 120°C | 1.000 | 20.0% | Hypothetical reference condition |
| 35°C | 110°C | 0.917 | 18.3% | Request configuration-specific validation |
| 40°C | 105°C | 0.875 | 17.5% | Check winding peaks and actual cycle length |
| 50°C | 95°C | 0.792 | 15.8% | Confirm all assembly temperature limits |
| 60°C | 85°C | 0.708 | 14.2% | May be outside the permitted ambient range |
| 70°C | 75°C | 0.625 | 12.5% | Reject if outside the supplier's ambient rating |
For quotation comparison, send the same timing and ambient profile to every supplier. Ask each to identify the tested operating point, the limiting component, and any mandatory cooling or dwell. This makes a qualified lower-duty proposal easier to compare with a headline “100% duty” claim that lacks conditions.
Need to turn the timing example into a sourcing discussion? Send your load, speed, cycle timing, and maximum ambient for review. Include the existing part number and current trace if you are investigating overheating.
7. Comparative Architecture Matrix: Sourcing by Duty Cycle Requirement
This matrix compares design trade-offs, not guaranteed duty percentages, price ratios, or force ratings. Obtain the permitted load-speed-temperature envelope for each quoted configuration.
| Architecture | Potential thermal advantage | Main limitation | Evidence to request | Typical selection question |
|---|---|---|---|---|
| Brushed DC with Acme screw | Simple drive and potentially low standby power | Sliding losses and brush wear | Load-current curve, duty window, screw efficiency | Is occasional adjustment sufficient? |
| Brushed DC with worm gearing | Compact reduction and high output torque | Gear losses and possible heat concentration | Combined gearbox/screw efficiency and heat-run record | Does the packaging justify the losses? |
| Brushed DC with ball screw | Lower screw loss at a matched output point | Backdriving and remaining brush maintenance | Brake rating, continuous-current limit, tested cycle | Can existing DC controls be retained? |
| BLDC with ball screw | Stationary windings can improve heat conduction; no brushes | Driver losses, brake heat, and installation cooling | Winding/driver temperatures and rated operating envelope | Is higher utilization worth the control change? |
| Fan-cooled electric cylinder | Forced airflow can lower external thermal resistance | Fan reliability, contamination, and cooling-path restrictions | Airflow conditions, fan monitoring, ingress requirements | Is cooling available during dwell as well as motion? |
| Servo electric cylinder | Controlled motion profile and access to motor thermal data | Peak force differs from sustainable force | RMS torque/current, screw life, brake duty, drive limits | Does the full trajectory meet continuous ratings? |
A low-duty application can still require a sophisticated actuator for precision, diagnostics, or environmental resistance. Conversely, a continuous-rated motor cannot overcome a screw, brake, or controller that is unsuitable for the specified cycle.
8. Engineering Solutions: How Custom Actuator Design Addresses Thermal Bottlenecks
Oversizing may lower relative motor load, but it also changes mass, mounting space, power supply, and cost. Review the loss budget before deciding whether a larger motor, a different screw, or better heat transfer offers the most useful improvement.
8.1 Converting Acme Screws to Ball Screws
Screw efficiency affects motor input power at the same thrust and linear speed. As an illustrative calculation, 100 W of useful screw output requires about 286 W input at an assumed 35% efficiency, leaving 186 W as screw loss. At an assumed 90% efficiency it requires about 111 W input, leaving 11 W as screw loss. These efficiency assumptions are examples, not measured values for a quoted actuator.
The comparison isolates the screw. Gear, bearing, seal, and motor losses remain. A ball screw can reduce required torque, but the amount depends on lead, preload, lubrication, and loading; the example does not establish a fixed motor-current or winding-temperature reduction. More efficient screws also require an explicit backdriving and holding assessment.
8.2 Brushless DC (BLDC) Motor Integration
In a common internal-rotor BLDC design, copper windings sit on a stationary stator that can conduct heat into the chassis. Removing brushes also removes brush maintenance. The rotor still has an air gap, and winding-to-housing insulation, interfaces, and mounting affect thermal resistance. Ask for the proposed motor's continuous rating with the actual driver and cooling arrangement instead of assuming a fixed percentage improvement over brushed DC.
8.3 Finned Aluminum Housings and Thermal Potting
External fins can increase effective heat-transfer area, but their benefit depends on orientation, airflow, surface temperature, and fouling. Do not equate an ingress rating with an airtight construction or a specific thermal penalty. Thermally conductive potting may improve selected conduction paths while adding mass and making repair difficult. Have the supplier document material compatibility, electrical insulation, and thermal-cycle durability for the final construction.
8.4 Embedded Thermal Sensors and Smart Telemetry
A winding sensor can reveal conditions that an external housing measurement misses. Confirm sensor location, tolerance, controller input compatibility, alarm threshold, and response delay. A PTC temperature sensor normally works with a suitable monitoring input; it is not generally placed in series with the full motor current. A bimetal switch must have suitable electrical ratings if it interrupts motor power directly.
Agree how the machine stops and recovers after an overtemperature event. Automatic thermal reset does not itself provide safe restart behavior. Software speed reduction can help some motion profiles, but reducing speed at unchanged torque can lengthen powered time. Validate the complete cycle rather than assuming slower always means cooler.
9. Method & Boundaries: When to Keep an Intermittent-Duty Design
A continuously rated platform is not automatically the best purchase. Consider these boundaries before paying for extra thermal capacity:
- Static holding dominates: A ball screw may backdrive and need a rated brake or mechanical restraint. An Acme screw may resist backdriving, but lead angle, lubrication, wear, vibration, and the external load affect that behavior. Do not treat frictional self-locking alone as a safety function for a supported load.
- Motion is infrequent: Thirty seconds of operation every two hours is about
30 / 7,200 × 100 = 0.42%duty. If the individual run fits the supplier limit, continuous capability may add little thermal value. Include any holding current and emergency operating sequence in that assessment. - Simple controls matter: A brushed motor can use appropriately rated relays or an H-bridge. A BLDC motor needs electronic commutation, sometimes integrated inside the actuator. Compare the complete supply, controller, brake, wiring, and service requirements rather than motor price alone.
For an OEM release decision, ask what evidence would change the choice. A measured winding-temperature exceedance, an unacceptable brush replacement interval, or an unavailable cooling path is more useful than a general preference for one motor topology.
10. OEM Procurement and Engineering Validation Checklist
Use this checklist to turn a duty-cycle percentage into a reviewable supplier requirement:
- Define the entire cycle: Extension, retraction, dwell, energized holding, starts per hour, longest uninterrupted run, and shift pattern. State load and speed in each segment.
- Define the environment: Normal and maximum local ambient, enclosure, mounting orientation, heat sources, airflow, and ingress requirements.
- Request rating conditions: The supplier's declared reference temperature, cycle window, maximum on-time, force-speed limits, and configuration-specific derating data.
- Identify all thermal limits: Insulation-system class, allowed winding temperature, controller limit, magnets, lubricant, seals, brake, and relevant surface-temperature requirements.
- Document the evidence gap: Where curves are unavailable, agree an application heat-run test. A missing public curve does not prove a false rating, but it leaves the proposed operating point unverified.
- Verify protection behavior: Sensor location, trip setting, current limiting, fault indication, stopping behavior, and restart control. Record behavior under a stalled or obstructed stroke.
- Validate the final assembly: Test the proposed motor, gearbox, screw, controller, brake, supply, and representative mounting at the agreed worst-case profile.
- Agree acceptance criteria before testing: Repeat cycles until the agreed temperature-stability criterion is reached. Log ambient, winding estimate or sensor reading, housing and controller temperature, current, speed, and faults. Check the highest temperatures against the approved limits and retain the test configuration and report revision.
When using a resistance-based winding-temperature method, record cold and hot resistance and the reference temperature, with the appropriate conductor coefficient and measurement procedure. A resistance difference alone is not a temperature measurement. A single successful stroke is also insufficient evidence for an eight-hour repeating process.
11. Frequently Asked Questions (FAQ)
Q1: What is the reference time window for linear actuator duty cycle?
A: Use the manufacturer's declared window and maximum on-time. If a specific rating permits two minutes on and eight minutes off, that is 20% over ten minutes. Another 20% sequence may have a different thermal peak. The percentage alone cannot determine an approved continuous run time.
Q2: Why can an actuator overheat at 50% of rated load?
A: Lower load can reduce current, but iron, friction, seal, controller, and brake losses may remain. High ambient temperature or inadequate cooling can still exhaust the available heat budget. Check measured current and the supplier's part-load duty curve rather than assuming half load allows twice the duty.
Q3: How do rapid start-stop cycles affect duty cycle?
A: Starts can add appreciable winding heating even when total running time looks low. Record the current waveform, acceleration time, starts per hour, and any electrical braking. Discuss S4 or another appropriate duty type with the supplier; a current-limited controller can make the profile very different from a direct-on-line start.
Q4: Can external air cooling increase the duty rating?
A: It may lower housing-to-air thermal resistance, but internal winding hot spots can remain limiting. Cooling changes require supplier review and a representative heat run. Include airflow interruption, contamination, and the resulting protection response in the machine assessment.
Q5: How do a self-resetting bimetal switch and a PTC sensor differ?
A: A bimetal switch changes contact state at a selected temperature and may reset after cooling. Its reset does not necessarily command motion; restart depends on the circuit. A PTC temperature sensor increases resistance sharply near its response region and requires a compatible monitoring input. Neither mechanism alone establishes safe machine restart.
Q6: Does a BLDC ball-screw actuator guarantee 100% duty?
A: No. It can offer useful efficiency, heat-transfer, and maintenance advantages, but the full actuator still needs a declared continuous operating envelope. Confirm force, speed, stroke, ambient, cooling, brake behavior, screw life, and controller limits for the quoted part number.
12. Conclusion & OEM Engineering Next Steps
Calculate ED% first, then compare the full load-speed-time profile with the supplier's operating envelope. Keep average heating separate from peak winding temperature, and distinguish insulation class from the lower limit of another assembly component. A BLDC label, finned housing, or large thrust number does not replace this assessment.
For an existing overheating problem, collect a current trace, actual cycle timing, local ambient, and the controller fault history before changing hardware. For a new platform, request a configuration-specific thermal qualification plan with the quotation. These inputs support a practical choice between an intermittent brushed actuator, a more efficient drivetrain, and a continuous-rated system.
Partner with Custom Linear Actuator Specialists
- Check your timing: Use the continuous-duty linear actuator guide and powered-time calculator to calculate nominal ED% and prepare questions for suppliers. It does not calculate an approved ambient derating curve or motor size.
- Prepare an engineering RFQ: Contact our team with your actuator duty profile. Include thrust in each direction, stroke, speed, timing, local maximum ambient, mounting constraints, expected annual cycles, and production quantity. Ask which test evidence and custom options are available before committing to a design.
13. Verifiable Sources and Engineering References
Sources checked November 4, 2026. The catalogue records identify standards and their scope; full clause-level compliance requires the applicable standard and supplier documentation. The numerical examples above are this guide's calculations, not test results from these organizations.
- IEC — IEC 60034-1:2026, Rotating electrical machines — Part 1: Rating and performance. Current catalogue record for motor rating and performance terminology; it replaces the 2022 edition. Confirm the declared duty and applicable edition with the motor supplier. It does not certify a complete linear actuator or prescribe the example derating curve.
- IEC — IEC 60085:2007, Electrical insulation — Thermal evaluation and designation. Scope covers thermal evaluation and class assignment for insulating materials and insulation systems. It is not evidence of a universal ten-degree actuator-life rule or an assembly operating-temperature limit.
- LINAK — Linear actuator operating principles and product specifications. Manufacturer overview of motor, gear, screw, and control options, with links to model data sheets and manuals. Use the selected model's controlled documentation for duty and ambient limits; this overview does not supply a universal thermal time constant or derating multiplier.
Author
Categories
More Posts

Linear Actuator Market Update (2026-W27): Proclamation 11032 Shifts Section 232 Tariff Thresholds and RFQ Sourcing Strategies
Week 27 brief for custom linear actuator buyers: Proclamation 11032 lowers the U.S.-origin metal threshold to 85%; update RFQs and HTS evidence before award.

Linear Actuator Market Update (2026-W15): Tariff Windows, EU Machinery Amendment, and RFQ Controls
Decision-level weekly brief for actuator buyers: verified U.S./EU signals in the last 30 days, what changed, what did not verify, and what OEM teams should change in RFQs now.
PFAS-Free Linear Actuators: EU REACH Sourcing Guide
Source PFAS-free linear actuators for EU REACH readiness: audit PTFE/PFPE greases, compare seal alternatives, and contact engineering for RFQ review.